UKG-5/8
Gas utilization compressor station UKG-5/8 is used for the utilization of mine gas (active and closed mines) by its burning in a special chamber Gas utilization compressor station UKG-5/8 is used for the utilization of mine gas (active and closed mines) by its burning in a special chamber. This helps to prevent the discharging of the harmful greenhouse gas – methane (СН4) or to supply the equipment of energy use (to get electricity and heat). The main consumers of the station are enterprises of food recycling, agriculture, coal and oil industries.
| Parameters | Significance or description |
| Station in total |
| Combustion environment |
Mine gas (25% and more CH4)
|
| Dimensions , mm, not more |
Length |
6058 |
| width |
2438 |
| height |
2591 |
| Dimensions of pipe, mm not more |
diameter |
1900 |
| height |
6326 |
| Weight of the station with a pipe, kg, not less |
12000 |
Nominal capacity, kW, not more
|
60 |
| Supply voltage, V |
380 |
| By machine room |
Compressor type
|
Rotor with an wear-resistant interior cover |
| Compressor productivity, at the nominal operation conditions m3/s (m3/min) |
0,17-0,43 (10-26) |
| Pressure differentia MPa (kgs.cm2) |
0,01-0,05 (0,1-0,5) |
| Type of drive |
Drive belting, frequency transformer |
| Capacity of drive electro motor, kW, not more |
45 |
| Rotation frequency of motor shaft, from -1 (rpm) |
24,08-49,25 (1445-2955) |
| Inlet gas temperature, К(S), not more |
303 (30) |
| By section of combustion chamber |
| Outlet gas temperature, К(S), not more |
383 (110) |
| Dimensions of combustion chamber, mm, not more |
lenght |
2308 |
| width |
2268 |
| height |
2354 |
| Heat power, MW |
nominal |
5 |
| max |
8 |
| Combustion temperature К(S), not more |
1473 (1200) |

|
Representatives of concern
|