Compressor plant EPKU 1/10-01
org_5ee7epku-1-10-01.jpg
Technical Date
| Title |
Norm |
EPKU 0,8/10-02 |
EPKU 0,8/10-03 |
EPKU 1/10-01 |
EPKU 1,7/10-01 |
|
Volume flow, nm³/min
|
0,8 |
1,1 |
1,7 |
|
Delivery pressure, kgf/cm²
|
10 |
| Mode of operation |
seamlrss |
| Air tank capacity, m³ |
0,5 |
0,8 |
0,5 |
| Adjustment of productivity |
start-stop |
| Cooling |
air |
| Consumed power,kW |
11 |
15 |
| Line voltage, V |
380 |
| Overall dimensions, mm: |
|
|
lenght
|
1960 |
2855 |
1875 |
|
width
|
700 |
830 |
|
height
|
1130 |
1505 |
| Weight, kg |
385 |
450 |
495 |

|